Material Safety Data Sheet
Science Stuff, Inc.
1104 Newport Ave
Austin, TX 78753
Phone (512) 837-6020
Chemtrec 800-424-9300
24 Hour Emergency Assistance
Section 1 Identification
Product Number:C1407 
Health:
Flammability
Reactivity
Hazard Rating:
LeastSlightModerateHighExtreme
01234
NA = Not Applicable NE = Not Established
Product Name:Cadmium Chloride  Reagent A.C.S., Crystal
Trade/Chemical Synonyms 
Formula:CdCl’½2 1/2 H’O
RTECS:EV0178000 
C.A.SCAS# 7790-78-5
Section 2 Component Mixture
Sara 313ComponentCAS Number%DimExposure Limits:
Cadmium Chloride  CAS# 7790-78-5 100% W/W OSHA TWA 0.2 mg/mƒ (Cd) 
Section 3 Hazard Identification (Also see section 11)
May be fatal if inhaled, swallowed or absorbed thru the skin Avoid all contact. Use with adequate ventilation. Wash thoroughly after use. Keep container closed. 
Section 4 First Aid Measures
May be fatal if inhaled, swallowed or absorbed thru the skin Avoid all contact. Use with adequate ventilation. Wash thoroughly after use. Keep container closed.

FIRST AID: SKIN: Remove contaminated clothing. Wash exposed area with soap and water. If symptoms persist, seek medical attention

EYES: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid. INHALATION: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen

INGESTION: If swallowed, induce vomiting immediately after giving two glasses of water. Never give anything by mouth to an unconscious person.
Section 5 Fire Fighting Measures
Fire Extinguisher Type:Any means suitable for extinguishing surrounding fire
Fire/Explosion Hazards:Thermal decomposition produces highly toxic fumes.
Fire Fighting Procedure:Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and clothing.
Section 6 Accidental Release Measures
Evacuate area. Wear self-contained breathing apparatus and protective clothing. Eliminate all sources of ignition.
Section 7 Handling and Storage
Store in a cool, dry, well-ventilated place away from incompatible materials. Wash thoroughly after handling. 
Section 8 Exposure Controls & Personal Protection
Respiratory Protection:NIOSH/MSHA-approved respirator
Ventilation: Mechanical: Hand Protection:NIOSH Approved Gloves
Local Exhaust: Eye Protection:Splash Goggles
Other Protective Equipment: Wear appropriate clothing to prevent skin exposure
Section 9 Physical and Chemical Properties
Melting Point:568° CSpecific GravityInformaiton not available
Boiling Point:960° C Percent Volatile by Volume:0
Vapor Pressure:10mm @ 656°C Evaporation Rate:0
Vapor Density: Information not available Evaporation Standard:
Solubility in Water: Soluble Auto ignition Temperature: Not applicable
Appearance and Odor: Colorless crystals , odorless Lower Flamm. Limit in Air: Not applicable
Flash Point: N/A Upper Flamm. Limit in Air: Not applicable
Section 10 Stability and Reactivity Information
Stability: StableConditions to Avoid: None known
Materials to Avoid:
Oxidizing agents
Hazardous Decomposition Products:
None
Hazardous Polymerization:Will Not Occur
Condition to Avoid:None known
Section 11 Additional Information
Effects of overexposure.Acute: Material is irritating to mucous membranes and upper respiratory tract. Chronic: Carcinogen. May cause congenital malformation in the fetus. Exposure can cause damage to the kidneys and lungs. 
DOT Classification: Cadmium Compounds (Cadmium Chloride), 6.1, UN2570, PG III
DOT regulations may change from time to time. Please consult the most recent version of the relevant regulations.
Revision No:0Date Entered: 9/1/2006 Approved by: WPF

The information contained herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty is expressed or implied regarding the completeness or accuracy of this information, whether originating from Science Stuff, Inc. or from an alternate source. Users of this material should satisfy themselves by independent investigation of current scientific and medical information that this material may be safely handled.